Venturi Meter Lab pdfs

Searching:
Download
Venturi Meter Lab - Fast Download

Download Venturi Meter Lab from our fatest mirror

Lab 2: Venturi Meter - Michigan Technological University

3784 dl's @ 6839 KB/s

pdf
Lab 2: Venturi Meter - Michigan Technological University

CE 3620: Water Resources Engineering Spring 2014 . Lab 2: Venturi Meter . BACKGROUND . A Venturi meter is a tube with a constricted throat that increases velocity and decreases

http://www.cee.mtu.edu/~vgriffis/CE%203620%20materials/CE3620-Labs/Lab%202-Venturi%20Meter.pdf

Date added: December 26, 2011 - Views: 620

pdf
Hydraulics Laboratory Experiment Report - A H M 531

Hydraulics Laboratory Experiment Report Name: Ahmed Essam Mansour Section: "1", Monday 2-5 pm Title: Venturi Meter and Orifice Meter Date: 6 November, 2006

http://ahm531.com/lab-reports/hydraulics-lab/reports/1/Venturi%20Meter%20and%20Orifice%20Meter.pdf

Date added: February 3, 2012 - Views: 250

pdf
venturi meter lab report

Lab 2: Venturi Meter - Michigan Technological University. http://www.cee.mtu.edu/~vgriffis/CE%203620%20materials/CE3620-Labs/Lab%202-Venturi%20Meter.pd f CE 3620: Water Resources Engineering Spring 2014 . Lab 2: Venturi Meter . BACKGROUND .

http://www.pdfspath.com/download/venturi%20meter%20lab%20report.pdf

Date added: July 24, 2014 - Views: 1

pdf
Bernoulli Balance Experiments Using a Venturi

The venturi meter is one of the more common full-bore meters, i.e. meters that operate by sensing all of the fluid in the pipe or channel. In the operation of a venturi meter, upstream and

http://www.asee.org/documents/sections/midwest/2011/ASEE-MIDWEST_0008_6430aa.pdf

Date added: April 14, 2012 - Views: 35

pdf
Department of Mechanical Engineering Venturi Meter - FIT Staffweb

Department of Mechanical Engineering Venturi Meter OBJECTIVE: To find the water flow rate using the Venturi meter and the pressure distribution along

http://staff.fit.ac.cy/eng.ca/Fluids%20Lab%20Venturi%20meter_4.pdf

Date added: May 4, 2013 - Views: 9

pdf
faculty.washington.edu

Venturi Lab.doc; saved 9/23/2005 4:59:00 PM CEE 342 Laboratory Exercise: Flow Meter Calibration A “venturi meter” is a device for determining fluid velocities based on the pressure

http://faculty.washington.edu/markbenj/CEE342/Venturi%20Lab.pdf

Date added: December 23, 2011 - Views: 85

pdf
ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW

ECH 4224L Unit Operations Lab I Fluid Flow 1-4 Figure 1. Venturi meter. The figure is taken from documentation by Lambda Square Inc. Complete

http://www.che.ufl.edu/ren/unit-ops-lab/ech4224L/FF/FF-theory.pdf

Date added: April 27, 2013 - Views: 29

pdf
Flow Measurement Experiment - Cal Poly Pomona

ME313L Fluid Mechanic Lab Manual (DRAFT) 3 Considering the geometry of the Venturi , the mass flow will be m 1=0.962 • h A − h B 1 2 kg/s 2) Orifice Meter

http://www.csupomona.edu/~padashner/313/FlowMeasurement.pdf

Date added: December 3, 2011 - Views: 242

pdf
FLOW MEASUREMENT (Venturi meter, Orifice Plate and Rotameter

FLOW MEASUREMENT (Venturi meter, Orifice Plate and Rotameter) OBJECTIVES To study the characteristics and applications of various flow measuring device

http://fetweb.ju.edu.jo/ME/courses/labs/measurements/labsheet/Experiment%20No%203%20flow%20measurements.pdf

Date added: October 18, 2012 - Views: 105

pdf
Venturi Meters Constructed with Pipe Fittings: An Under ...

Actual head loss through a Venturi meter is commonly quite small compared with opportunities for head recovery that might exist at a pipe exit. As an example, for the site shown in Figure 6, addition of pipe fittings to create an underwater discharge would

http://www.usbr.gov/pmts/hydraulics_lab/pubs/PAP/PAP-1050.pdf

Date added: June 28, 2012 - Views: 6

pdf
research.me.udel.edu

venturi.dvi Created Date: 10/27/2004 6:29:02 PM ...

http://research.me.udel.edu/~prasad/meeg331/labs/venturi.pdf

Date added: February 3, 2012 - Views: 8

pdf
FLUID MECHANICS

FLUID MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY EXPERIMENT: 2 VENTURI METER INTRODUCTION: The Ventura meter used in this experiment consists of successive converging, uniform

http://deploy.virtual-labs.ac.in/labs/eerc03/exp5/2.%20Venturi_meter.pdf

Date added: November 24, 2013 - Views: 34

pdf
Experiment (4): Flow measurement - الصفحات الشخصية

Hydraulics Lab (ECIV 3122) ... The flow is determined using a sudden enlargement, venturi meter, orifice plate, elbow and a rotameter. The pressure drop associated with each meter is measured directly from the manometers. Purpose: To ...

http://site.iugaza.edu.ps/mymousa/files/Experiment-4-hydraulics-lab-.pdf

Date added: March 5, 2014 - Views: 1

pdf
APPENDIX I: FLOW NOZZLE CALIBRATION - U of M: Department of ...

Venturi meter located downstream of the supply fan. The uncertainty of mass flowrate measured by the CEESI subsonic Venturi is estimated to be 1.0% at a 95% confidence level. A total of three tests were performed on the subsonic flow meters.

http://www.me.umn.edu/courses/me4131/LabManual/AppIVenturiCalibration.pdf

Date added: May 5, 2013 - Views: 8

pdf
Experiment (4): Flow measurement Introduction

The flow is determined using a sudden enlargement, venturi meter, orifice plate, elbow and a rotameter. The pressure ... Fluid Mechanics Lab Experiment (4): Flow measurement 2 Instructors : Dr. Khalil M. ALASTAL ...

http://site.iugaza.edu.ps/mymousa/files/Experiment-4-Fluid-mechanics-lab.pdf

Date added: December 30, 2013 - Views: 2

pdf
FLUID MECHANICS - University of Illinois at Chicago

The main goal of the experiment is to utilize the Venturi meter to measure liquid flow rate, and provide comparisons between experiment and theory via the Bernoulli ... Follow the lab report write-up format given in this manual. Apparatus 1.

http://www.uic.edu/classes/me/me211/Lab/lab3.pdf

Date added: November 24, 2012 - Views: 43

pdf
FIELD FLOW TESTING OF SIX LARGE VENTURI METERS

Flow at Venturi measured by St. Anthony Falls Hydraulic Lab using insertion type magnetic current meter Flow measured at Venturi A Flow measured at Venturi B v . Abbreviations ... compared to the flow measured by the Venturi meter being calibrated. To eliminate possible telemetry ...

http://conservancy.umn.edu/bitstream/108533/1/pr312.pdf

Date added: October 15, 2012 - Views: 14

pdf
Utah Water Research Laboratory, Utah State University

A 60-inch venturi meter calibration in the Lab. The 60-inch venturi meter was a scale model of a 180-inch meter. The model included the scaled field piping (view shows approach piping) Formed inlet sump model study.

http://uwrl.usu.edu/www/faculty/BTullis/Pres1.pdf

Date added: August 22, 2013 - Views: 1

pdf
Alqudspub.com Fluid Mechanics Lab. ENME 312

Fluid Mechanics Lab. ENME 312 The objective of Fluid Mechanics Lab would be able to: • Name different types of flow meters, ... • To distinguish the constructional differences between orifice meter and venturi meter and Rotameter.

http://alqudspub.com/files/1263049628/file/Fluid%20Mechanics(1).pdf

Date added: June 5, 2013 - Views: 10

pdf
Utah Water Research Laboratory, Utah State University

A 60-inch venturi meter calibration in the lab. The 60-inch venturi meter was a scale model of a 180-inch meter. The model included the scaled field piping. 60-inch model field piping upstream of the test meter. A recent research project studied the cavitation characteristics in sleeve

http://uwrl.usu.edu/www/faculty/BTullis/Pres2.pdf

Date added: May 19, 2013 - Views: 1

pdf
MEASUREMENTS WITH FLOW METERS - University of Minnesota Duluth

data for a venturi meter and an orifice meter. Determine the relationship between volumetric flow rate, Q, and the pressure drop, ΔP, for each meter Is it linear? ... Lab No.: Lab 1 Tuesday 12:00 - 4:50 PM Lab 2: Thursday 12:00 - 4:50 PM Lab ...

http://www.d.umn.edu/~dlong/exflwmtr.pdf

Date added: January 28, 2012 - Views: 76

pdf
MEASUREMENT OF AIRFLOW - Wallace Racing

Lab The schematic of the apparatus is shown in figure 1. The air flowrate will be measured with: (a) Orifice plate, (b) Venturi meter and (c) Pitot-static tube. Familiarize yourself with the apparatus and the procedure for performing the experiment.

http://www.wallaceracing.com/fluidsI_lab2.pdf

Date added: March 12, 2012 - Views: 2

pdf
AE 547 EXPERIMENTAL AERODYNAMICS LABORATORY PROCEDURE VENTURI ...

middle east technical university department of aerospace engineering ae 547 experimental aerodynamics laboratory procedure venturi meter (h5) anil gÜÇlÜ

http://www.ae.metu.edu.tr/~ae547/lab13/Lab_1_procedure.pdf

Date added: December 30, 2013 - Views: 1

pdf
VENTURI METER REHAB - Primary Flow Signal

VENTURI METER REHAB Rehabilitation of Venturi Flow Primaries for Extended Service Life ... performance, hydraulic lab calibration (if required), and preparation of new flow calculations based on rehabilitation results allowing the production and use of

http://www.primaryflowsignal.com/images/stories/ProductsPDFs/ventur_meter_rehab.pdf

Date added: September 4, 2013 - Views: 1

pdf
Flowmeter Calibration: How, Why, and Where Deviation From a ...

Lab By Jesse Yoder August 01, ... using a master meter, or weighing the flow to get a gravimetric reading of ... positive displacement meters, venturi meters, and Coriolis meters. In the U.S., master meters are often calibrated at a flow lab that has been certified by the National

http://www.flowresearch.com/articles/Control%208_1_00.PDF

Date added: January 28, 2012 - Views: 50

pdf
MESB 203 LAB NO. 5 WATER FLOW RATE MEASUREMENT PRELAB QUESTIONS

MESB 203 Lab No.5 July 2008 51 Knowing that Q ideal = A 2V2, thus: The above is for an ideal flow. For venturi tube and the orifice, the equation must be multiplied

http://metalab.uniten.edu.my/~hanim/mesb333labmanual/Lab5.pdf

Date added: September 2, 2013 - Views: 3

pdf
Thermodynamics Fluid Mechanics - SZABIST | Discover yourself

Fluid Mechanics Lab ... To determine the discharge coefficient of the venturi meter To measure flow rate with venturi meter To demonstrate Bernoulli’s Theorem To determine the discharge coefficient of the venturi meter

http://khi.szabist.edu.pk/pdf/Thermo%20Fluids%20Lab.pdf

Date added: September 12, 2013 - Views: 2

pdf
Experiment No.4: Flow through Venturi meter Background and Theory

Experiment No.4: Flow through Venturi meter Background and Theory Introduction Flow meters are used in the industry to measure the volumetric flow rate of fluids.

http://solve.nitk.ac.in/dmdocuments/Chemical/theory_venturi.pdf

Date added: January 5, 2012 - Views: 162

pdf
ATOOMUS - A H M 531

Objective: Venturi: To study the principles of Venturi meter and to determine its coefficient Cd by comparing the measure flow rate with the ideal flow rate.

http://www.ahm531.com/lab-reports/hydraulics-lab/reports/2/5.Venturi%20&%20Orifice%20.pdf

Date added: February 3, 2012 - Views: 51

pdf
Measurement of Flow Rate, Velocity Profile and Friction ...

The Venturi meter with 5.08cm diameter is used to measure the total flow rate, while the other two are kept closed. ... Your lab report should include your plots of average velocity and flowrate versus x-position. You should answer

http://www.engineering.uiowa.edu/~fluids/Posting/Home/EFD/EFD_Lab2/lab2_Exercise_Note.pdf

Date added: February 21, 2013 - Views: 7

pdf
fluid Mechanics I - Jawaharlal Nehru Engineering College ...

Lab Incharge H.O.D. CIVIL . JNEC CIVIL/FM-I/AUG 2010 Page 2 ’FLUID MECHANICS -I’ EXPERIMENTS SUBJECT: - Fluid Mechanics-I CLASS: - Second Year Civil Engineering ... Venturi Meter 2) Orifice Meter 3) Pilot Tube . JNEC CIVIL/FM -I/AUG 2010

http://jnec.org/Lab-manuals/CIVIL/fluid%20Mechanics%20I.pdf

Date added: September 8, 2013 - Views: 11

pdf
CIEG-306 Fluid Mechanics Laboratory 6. FLOW RATE MEASUREMENT ...

5 c. Determine the volume flow rate Q as given by i. the Venturi meter Q v, ii. the orifice plate Q 0, and iii. the Rotameter Q r (using the calibration constants you just determined).

http://www.coastal.udel.edu/~thsu/course/Chap_6_Flow_mea.pdf

Date added: February 3, 2012 - Views: 28

pdf
EXPERIMENT 6 FLUID METERS IN INCOMPRESSIBLE FLOW

orifice meter, the venturi meter, the elbow meter and the nozzle meter are only a few. Each meter works by its ability to alter a certain physical characteristic of the flowing fluid and then ... Fluids_Lab_Manual08.doc Author: William Janna

http://www.computationaldesignlab.org/hnat/ME_Exp_Website/Fluid%20Meters/fluid-meters.pdf

Date added: September 8, 2013 - Views: 9

pdf
ME 388 -Senior Laboratory Centrifugal Pump Performance Experiment

Figure 1: Pump lab system schematic showing major components. ME 388 -Senior Laboratory Centrifugal Pump Performance Experiment 2 ... the venturi meter, A2 is the venturi throat area, and is the dynamic viscosity of water. 3. Create three graphs.

http://www.ohio.edu/people/bayless/seniorlab/pump.pdf

Date added: June 18, 2013 - Views: 5

pdf
MECHANICS of FLUIDS LABORATORY - University of Memphis

Equipment in the lab is delicate and each piece is used extensively for 2 or 3 weeks per semester. During the remaining time, each ... interest are an orifice meter and a venturi meter. These meters are calibrated in this experiment by using a pitot-static tube to measure the velocity,

http://www.me.memphis.edu/menews/Fluids_Lab_Manual.pdf

Date added: November 27, 2011 - Views: 229

pdf
Page 1 of 2 H10 Flow Measurement

Students measure flow using a Venturi meter, an orifice plate meter and a rotameter. Bernoulli’s equation works for each meter. Students find and compare the head losses associated with each meter, as well as those arising in a

http://facultad.bayamon.inter.edu/eperezd/MECN%203110%20Fluids/laboratorios/Lab%204/Annex2-Lab4-H10_0808.pdf

Date added: May 9, 2013 - Views: 5

pdf
che.ufl.edu

Lambda Square Inc. vvwW.lambdasquare.com Installation Disturbance Venturi Meter Upstream and Downstream piping requirements Minimum Recommended Pipe Diameters

http://che.ufl.edu/unit-ops-lab/experiments/FF/FF-Venturi-Meters.pdf

Date added: March 23, 2014 - Views: 1

pdf
lab experiment calibration of orificemeter - Bing

Related searches for lab experiment calibration of orifice meter HYDRAULICS LABORATORY EXPERIMENTS - The ... 2010 · Calibration of Orifice & Venturi Meter Document Transcript. CEBU INSTITUTE OF TECHNOLOGY N. Bacalso Avenue, Cebu City ...

http://pdfdirpp.com/download/lab-experiment-calibration-of-orificemeter.pdf

Date added: June 7, 2014 - Views: 1

pdf
LABORATORY TEST OF @RE 2-INCH SHUNTFLO METER MANUFACTURED BY ...

A 2-inch (5.1-cm) Venturi meter was installed 20 diameters down- e means of measuring 2-inch gate valve- meter and to bleed rs. Just downstream threaded to a vertical flow to a weighing tank determinations. designed for gas flow ot ...

http://www.usbr.gov/pmts/hydraulics_lab/pubs/HYD/HYD-590.pdf

Date added: June 29, 2012 - Views: 6

pdf
Pump lab Rubric - Ohio University

Pump Lab Notes Abstract • Must mention purpose is to measure flow and analyze pump performance • Must mention use of venturi meter • Key parameters – Range of the shaft rotational speed (RPMs)

http://www.ohio.edu/people/bayless/seniorlab/pumpnotes.pdf

Date added: June 18, 2013 - Views: 1

pdf
Identification of the measurement characteristic of the ...

Identification of the measurement characteristics of the CFVN mass flow meter 2 1 Introduction 1.1 Critical flow Venturi nozzle A critical flow Venturi nozzle (CFVN) is a convergent-divergent restriction inserted into a

http://lab.fs.uni-lj.si/lasin/wp/IMIT_files/neural/doc/seminar7.pdf

Date added: July 9, 2013 - Views: 1

pdf
CE323 Hydraulic Laboratory Table of Contents Lab # Title ...

Lab # Title Tentative Date 1 Flow measurement and energy loss in pipes September 2 Water hammer, wave speed, line pack, and attenuation September 3 Centrifugal pump October 4 Pelton turbine October 5 Flow ... Calibrate a Venturi flow meter. 2.

http://www.webpages.uidaho.edu/CE322/Downloads/labbook.pdf

Date added: January 15, 2014 - Views: 1

pdf
CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-1 ...

Analysis Calculate the discharge coefficient for the Venturi meter and the orifice meter (or that for the nozzle meter, if it is at the unit) for, at least five different values of the flow

http://www.chme.ncc.metu.edu.tr/chme_lab_manuals/Flow_measurements.pdf

Date added: March 12, 2014 - Views: 1

pdf
Measuring Discharge with a Rectangular Weir TA: Caliente

CE 195 2009 2 Figure 2: Lab Materials Materials • 6 meter re-circulating flume with high-flow venturi • Plexi-glass weir plate • Aluminum cross plate

http://www.uvm.edu/~watercmp/fc2009/seminar/FlumeExercise.pdf

Date added: April 12, 2013 - Views: 3

pdf
LOCAL LOSSES IN PIPE FLOWS Principle Introduction

Venturi Meter 7, 11 4. 90° Bend 12, 15 4. 90° Bend 12, 15 NOTE: Only the Venturi and orifice meters have pressure tabs located immediately upstream and downstream the flow obstruction device. For all other situations localized energy losses at

http://www.engineering.uiowa.edu/~cfd/pdfs/53-071/lab3.pdf

Date added: December 20, 2011 - Views: 6

pdf
ANNA UNIVERSITY OF TECHNOLOGY - COIMBATORE

ME 2208 FLUID MECHANICS AND MACHINERY LAB 1. Determination of the coefficient of discharge of given Orifice meter. 2. Determination of the coefficient of discharge of given Venturi meter.

http://pacetmechanical.weebly.com/uploads/6/1/9/7/6197211/fluid_mechanics_ans_machinery_-_lab_manual.pdf

Date added: June 8, 2012 - Views: 64

pdf
Page 1 of 2 H40b Venturi Flow Meter - TecQuipment

H40b Venturi Flow Meter Page 2 of 2 FLUID MECHANICS Description A popular flow meter for use with TecQuipment’s Flow Meter Calibration unit (H40). It shows the accuracy and use of a venturi flow meter. This flow meter quickly and easily fits into place between

http://www.tecquipment.com/Datasheets/H40b_0213.pdf

Date added: May 4, 2013 - Views: 1

pdf
CHE 253M Experiment No. 3 LIQUID FLOW MEASUREMENT

and a venturi meter. The experimental setup is shown in Figure 1. The water that exits ... In order to calibrate the flow meters used in this lab, you must compare the output of the various flow meters to that of a primary standard.

http://willson.cm.utexas.edu/Che253M/Files/Experiment%203%20Liquid%20Flow%20Fall%202013.pdf

Date added: October 7, 2013 - Views: 2

pdf
EXPERIMENT 7 VELOCITY AND FLOW RATE - College of Engineering ...

ME 310 Lab Manual, Spring 2004 University of Kentucky 3 7. Note the readings of the two manometers, rotameter, and turbine flow meter, and also

http://www.engr.uky.edu/~me310/Labs/exp7manual.pdf

Date added: July 7, 2012 - Views: 13

pdf
ST-II Lab manual - Jawaharlal Nehru Engineering College ...

Manual typically contains practical/Lab Sessions related ... Venturi 2. Measurement of Flow Using Rotameter 3. Measurement of Level Using Any Two, Techniques 4. Study and Characterization of pH Meter 5. Study and Characterization of Conductivity-meter 6. Measurement of Relative Humidity by ...

http://jnec.org/Lab-manuals/INSTRU/SE/SE-ST-II%20Lab%20manual.pdf

Date added: December 28, 2013 - Views: 1